*STEP
Beginning a step in an ABAQUS/Explicitanalysis
References:
“Procedures: overview,” Section 6.1.1 of the ABAQUS Analysis User’s Manual
*END STEP
Optional parameter:
NAME
Set this parameter equal to the name used to identifythe step on the output database. Stepnames in
the same input file must be unique.
NLGEOM
Set NLGEOM=YES (default) to indicate that geometric nonlinearity should be accounted for
duringthe step (stress analysis and fully coupled thermal-stress analysis only). Once the NLGEOM
option has been switched on, it will be active during all subsequent steps in the analysis. Set
NLGEOM=NO to perform a geometrically linear analysis during the currentstep.
The default value for the NLGEOM parameter in an ABAQUS/Explicit analysis is YES
unless the ABAQUS/Explicit analysis is an import analysis, in which cas et he default value of the
NLGEOM parameter is the same as the value of the parameter at the time of import.
Optional data lines:
First line:
1. Subheading for this step.
The subheading can be several lines long, but only the first 80 charactersof the first line will be saved
and printed as a subheading.
18.36–4
ABAQUS Version 6.1 Module: ID:
Printed on: