*SOILS
FACT OR
Set this parameter equal to the damping factor to be used in the automatic damping algorithm
(see “Solving nonlinear problems,” Section 7.1.1 of the ABAQUS Analysis U ser’s Manual) if
the problem is expected to be unstable due to local instabilitiesand the damping factor calculated
by ABAQUS/Standard is not suitable. This parameter must be used in conjunction with the
STABILIZE and CONSOLIDATIONparameters and overrides the automatic calculation of the
damping factor based on a value of the dissipated energy fraction.
STABILIZE
Include this parameter to use automatic stabilization if the proble m is expected to be unstable due
to local instabilities. Set this parameter equal to the dissipated energy fraction ofthe automatic
damping algorithm (see “Solving nonlinear problems,” S ection 7.1.1 of the ABAQUS Analysis
User’s Manual). If this parameter is omitted, the stabilization algorithm is not activated. If this
parameter is included without a specified value, the defaultvalue of the dissipated energy fraction
is 2 × 10−4. If the FACTORparamet er is used, any value of the dissipated energy fraction will be
overridden by the damping factor.
This parameter can be used only in conjunction with the CONSOLIDATIONparameter.
UTOL
This parameter will invoke automatic time incrementa tion. If both the UTOL and the CETOL
parameters are omitted, fixed time increments will be use d.
Set this parameter equal to the maximum pore pressure change permitted in any increment (in
pressure units) in a transient consolidation analysis. ABAQUS/Standard will restrict the time step
to ensure that thisvalue will not be exceeded at any node (except nodes with boundary conditions)
during any increment of the analysis.
Set this value equalto any nonzero value in a steady-state analysis (to activate automatic time
incrementation).
Data line to define incrementation for a soils analysis:
First (and only) line:
1. Initialt ime increment. This value will be modified a s required if the automatic time stepping
scheme is used; it will be used as a constant time increment otherw ise.
2. Timeperiod. If END=SS is chosen, the step ends after thistim e periodor when steady-state
conditions are reached, whichever comes first.
3. Minimum time increment allowed. If ABAQUS/Standard finds it needs a smaller time
increment than thisvalue, the analysis is terminated. Ifthis entry is zero, a default value of the
smaller of the suggested initial time increment or10−5 times the total tim e period is assumed.
Only used for automatic time incrementation.
4. Ma ximum time increment allowed. If this value is not specified, the upper limit is the total
time period. Only used for autom atic time incrementation.
18.21–2
ABAQUS Version 6.1 Module: ID:
Printed on: