*PERMEABILITY
Data lines to define fully saturated isotropic permeability (TYPE=ISOTROPIC):
First line:
1. k.(UnitsofLT
−1.)
2. Void ratio, e.
3. Temperature, .
4. Firstfield variable.
5. Second field variable.
6. Etc.,uptofivefieldvariables.
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greaterthan five):
1. Sixthfield variable.
2. Etc.,up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the variation.
Data lines to define fully saturated orthotropic permeability (TYPE= ORTHOTROPIC):
First line:
1. . (Units o f LT−1.)
2. .
3. .
4. Void ratio, e.
5. Temperature, .
6. Firstfield variable.
7. Second field variable.
8. Thirdfield variable.
Subsequent lines (only needed if the DEPENDENCIES parameterhas a value greater than three):
1. Fourth field variable.
2. Etc.,up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the variation.
Data lines to define fully saturated anisotropic permeability (TYPE=AN ISOTROPIC):
First line:
1. . (Units o f LT−1.)
2. .
3. .
4. .
5. .
16.6–2
ABAQUS Version 6.1 Module: ID: