*WIND
22.2 *WIND: Define wind velocity profile for wind loading.
Thisoptionisusedtodefineawindvelocityprofileforuseinapplyingloads.
Product: ABAQUS/Aqua
Type: Model data
Level: Model
Reference:
“ABAQUS/Aqua analysis,” Section 6.10.1 of the ABAQUS Analysis User’sManual
There are no parameters associated with this option.
Data line to define the wind velocity profile:
First (and only) line:
1. Air density, .
2. Reference height for wind profile, .
3. Localx-direction velocity constant, (default value 1.0).
4. Localy-direction ve locity constant, (default value 1.0).
5. x-directioncosine defining the direction of the unit vector (thewind local x-axis) with respect
to the global coordinate system. In three-dim ensional cases both x-andy-components are
needed; in two-dimensional cases only the x-component is used.
6. y-direction cosine defining the direction of the unit vector (thewind local x-axis) with respect
to the global coordinate system. Thiscomponent is not ne eded in two-dimensional cases.
7. (default value 1/7).
22.2–1
ABAQUS Version 6.1 Module: ID:
Printed on: