*VOLUMETRIC TEST DATA
Viscoelastic material model
References:
“Time domain viscoelasticity,”Section 17.7.1 of the ABAQUS Analysis User’s Manual
*VISCOELASTIC
Optional parameter:
VOLINF
To specify creep test data, set this parameter equal to the value of the long-term, normalized
volumetric compliance, .
To specify relaxation test data, set this parameter equal to the value of the long-term,
normalized volumetric modulus .
The volumetric compliance is related to the volumetric m odulus by .The
fitting procedure will use this value in the constraint .
Data lines to specify volumetric creep test data fora viscoelastic material:
First line:
1. Normalized volumetric (bulk) compliance .
2. Time .
Repeat this data line as often as necessary to give the compliance-timedata.
Data lines to specify volumetricrelaxation test data for a viscoelastic material:
First line:
1. Normalizedvolumetric (bulk) modulus .
2. Time .
Repeat this data line as often as necessary to give the modulus-time data.
21.7–3
ABAQUS Version 6.1 Module: ID:
Printed on: