*RETAINED EIGENMODES
17.16 *RETAINED EIGENMODES: Select the modes to be retained in a substructure
generation analysis.
This option selects the modes to be used in a substructuregeneration analysis. Themodes must be extracted
in a prior *FREQUENCY step and will include residual modes if they were activated. If this option is not
used, no modes will be used.
Product: ABAQUS/Standard
Type: History data
Level: Step
Reference:
“Defining substructures,” Section10.1.2 of the ABAQUS Analysis User’s Manual
Optional parameter:
GENERATE
If this parameter is included, each data line should give a first mode, ; a last mode; ;andthe
increment in mode numbers between these modes, i. Then, all modes going from to insteps
of iwill be added to the set. imust be an integer such that is a whole number (not a
fraction).
Data lines if the GENERATE parameter is omitted:
First line:
1. Listof modes to be used.
Repeat this data line as often as necessary. Up to 16 entries are allowed per line.
Data lines if the GENERATEparameter is included:
First line:
1. First mode number.
2. Last mode number.
3. Incrementin mode numbers between modes. The default is 1.
Repeat this data line as often as necessary.
17.16–1
ABAQUS Version 6.1 Module: ID:
Printed on: