*SHEAR TEST DATA
18.13 *SHEAR TEST DATA: Used to provide shear test data.
This option can be used only in conjunction with the *VISCOELASTIC option. The *SHEAR TEST DATA
option cannot be used for a viscoelasticm aterialif the *COMBINED TEST DATA option is used.
Products: ABAQUS/Standard ABAQUS/Explicit
Type: Model data
Level: Model
Using shear test data to define a viscoelastic material
References:
“Time domain viscoelasticity,”Section 17.7.1 of the ABAQUS Analysis User’s Manual
*VISCOELASTIC
Optional parameter:
SHRINF
Tospecify creep test data, set this parameter equal to the value of the long-term, normalized shear
compliance .
To specify relaxation test data, set this parameter equal to the value of the long-term,
normalized shear modulus . The shear compliance and shear modulus are related by
. The fitting procedure will use the specified value in the constraint
.
Data lines to specify creep test data:
First line:
1. Normalizedshear compliance .
2. Time t.
Repeat this data line as often as necessary to give the compliance-timedata.
Data lines to specify relaxation test data:
First line:
1. Normalized shear relaxation modulus .
2. Time t.
Repeat this data line as often as necessary to give the modulus-time data.
18.13–1
ABAQUS Version 6.1 Module: ID: