*VISCO
STABILIZE
Include this parameter to use automatic stabilization if the proble m is expected to be unstable due
to local instabilities. Set this parameter equal to the dissipated energy fraction ofthe automatic
damping algorithm (see “Solving nonlinear problems,” S ection 7.1.1 of the ABAQUS Analysis
User’s Manual). If this parameter is omitted, the stabilization algorithm is not activated. If this
parameter is included without a specified value, the defaultvalue of the dissipated energy fraction
is 2 × 10−4. If the FACTORparamet er is used, any value of the dissipated energy fraction will be
overridden by the damping factor.
Data line for a transient, quasi-static analysis:
First (and only) line:
1. Suggestedinitial time increment. Thisvalue should be reasonably correct (in agreement with
the strain change allowed with the CETOL parameter) but m ay be reduced if automatic time
incrementation is being used.
2. Time period of the step.
3. Minimum time increment allowed. If ABAQUS/Standard finds it needs a smaller time
increment than thisvalue, the analysis is terminated. Ifthis entry is zero, a default value of the
smaller of the suggested initial time increment or 10−5 tim es the total time period is assumed.
4. Maximumtim e increment allowed. Only u sed for automatic time incrementation. Ifthis value
is not specified, no upper limit is imposed.