*SURFACE BEHAVIOR

Repeat this data line in ascending order of overclosure value as often as necessary to define

the overclosure as a function of pressure. A minimum of two data lines are required. The

pressure-overclosure relationship is extrapolated beyond the last overclosure point by continuing the

same slope (see Figure 18.47–3).

ClearanceContactpressureExponential pressure-overclosure relationship p0
c0
Kmax
OverclosureFigure 18.47–1 Exponential pressure-overclosure relationshi p.
Overclosure
(i- 1) d
i d
K
i

= s

0

k

dflt

s

i-1
1
0
segment
i
P
ressure
i
k
L
s
s
r
d
= segment number
= default stiffness
= element length
= initial scale factor
= geometric scale factor
= overclosure factor
= r L = overclosure measur
e
dflt
elem
elem
0
Figure 18.47–2 Scale factor pressure-overclosure relationship.

18.47–4

ABAQUS Version 6.1 Module: ID: