194 Install and configure IP Trunk3.01 (and later) node
Remove existing I/O panel filter adapter
The standard I/O filter adapter is shielded metal with a black plastic insert
connector. The NTCW84JA adapter uses yellow warning labels to indicate
EMC filtering modifications and which MDF connection points can support
100BaseT connection.
Follow the steps in Procedure 8 "Removing the existing I/O panel filter
adapter" (page 194) to remove the existing I/O panel filter adapter.
Procedure 8
Removing the existing I/O panel filter adapter
Step Action
1Remove the ITG pack, or any other IPE pack, from the IPE shelf
card slot corresponding to the I/O Panelconnector to be removed.
Make sure to use the I/O panel connector which corresponds to the
left slot number of the DCHIP card.
2Remove the NT8D81AA Backplane to I/O Panel ribbon cable
assembly which is connected to the backplane side of the existing
block byreleasing the latching pins on the filter block and pulling the
NT8D81AA cable away.
3Unscrew the existing filter adapter from the I/O panel. There is one
screw on the lower front of the adapter and one screwon the upper
back of the adapter. Remove the adapter.
4Re-position the new NTCW84JA filter adapter in the now vacant I/O
panel opening. (See Figure 35 "NTCW84JA 50 pin I/O Panel Filter
Connector Block" (page 195).)
5Attach the new NTCW84JA to the I/O panel by securely fastening
the top back screw and the bottom front screw.
6Reconnect the NT8D81AA cable and secureit in place by snapping
shut the locking latches provided on the NTCW84JAconnector.
—End—