TM 3.1 OA and M procedure summary 349
ITG Card Properties Configuration window
The Configuration window for the IP trunk card contains the information
shown in Figure 139 "ITG Card Properties Configuration tab" (page
349). The ITG Card Properties Configuration window provides read-only
information. Go to the Node Properties Card Configuration window to
change this data. The Software version is retrieved from the card through
the MIB. If the card is not responding, the value is set to "Unknown".
Figure 139
ITG Card Properties Configuration tab
For more information about maintenance commands, see "Maintenance"
(page 389).
DSP maintenance window
If the IP trunk card is not responding, no DSP icons appear in the tree on
the left-hand side of the ITG Card Properties window.
click the required DSP icon in the tree on the left-handside of the ITG Card
Properties window. The DSP Maintenance window appears which contains
the state of the DSP and the Self Testcommand. click the Self Test button
to perform a self-test on the DSP.The command is sent to the IP trunk
card through SNMP.
If the DSP self-test fails, try to reset the card. If it fails again, replace the
card.