NTAG81CAFaceplate Maintenance cable 439
I/O Panel: P1 Signal Name P2, P3, P4, P5 Color
P1-31 P2 SHLD GRND
P1-50 P2 SHLD GRND
P1-23 RXDB+ P3-3 Green/White
P1-48 RXDB- P3-6 White/Green
P1-24 TXDB+ P3-1 Orange/White
P1-49 TXDB- P4-2 White/Orange
P1-18 RX+ P4-3 Green/White
P1-43 RX- P4-6 White/Green
P1-19 TX+ P4-1 Orange/White
P1-44 TX- P4-2 White/Orange
P1-10 P5-2 Black
P1-13 P5-10 Red
P1-11 P5-9 Black
P1-14 P5-11 White
P1-35 P5-4 Black
P1-38 P5-12 Green
P1-36 P5-5 Black
P1-39 P5-13 Blue
P1-12 P5-8 Black
P1-37 P5-15 Yellow
P1-25 P5-1 Black
NC Brown
P1-25 P5 SHLD GRND Bare
P1-50 P5 SHLD GRND Bare
NTAG81CAFaceplate Maintenance cable

The NTAG81CAcable connects an TM 3.1 PC or terminal to the IP trunk

card through the maintenance port connector on the IP trunk card faceplate.

Connect this cable directly to the 9-pin D-type RS-232 input (COM port) on

a standard PC. See Figure 150 "NTAG81CAPC maintenance cable" (page

440) and Table73 "NTAG81CA Faceplate Maintenance cable connections"

(page 440).

Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21December 2007
Copyright© 2007, Nor tel Networks
.