Electrical regulatory standards 455
Regulation identifier Regulatory agency
IEC 801-5 (level 4, preliminary) Surge Immunity (Basic Standard)
IEC 801-6 (preliminary) Conducted Disturbances (Basic Standard)
BAKOM SR 784.103.12/4.1/1 EMC/Safety (Switzerland)
SS-447-20-22 Sweden EMC standard
AS/NZS 3528 EMC (Australia/New Zealand)
NFC 98020 France EMC standard
Electromagnetic immunity regulations met by the Media Card 32-port trunkcard, along with the country’s regulation standards, are listed in "NorthAmerican dialing plan" (page 66).
Tabl e 86
Electro-magnetic immunityregulations met by the Media Card 32-port trunk card
Regulation Identifier Regulatory Agency
EN55024 Class B I/O conducted noise
EN61000-4-2 (level 4) ESD(Basic Standard)
EN61000-4-3 (level 2) RadiatedImmunity (Basic Standard)
EN61000-4-2 (level 3) Fasttransient/Burst Immunity (Basic Standard)
EN61000-4-5 (level 4, preliminary) Surge Immunity (Basic Standard)
EN61000-4-6 (preliminary) Conducted Disturbances (Basic Standard)
EN6100-4-11 Dips,Interruptions (system level)
EN61000-3-2 Harmonics& Flickers (system level)
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21December 2007
Copyright© 2007, Nor tel Networks
.