394 Maintenance
Alarm Description Fault Clearing Action
ITG0301 DSP channel not responding. DSP
channel is disabled. Card sends
message to the system to busy the
trunk. This ensures that user’s calls go
through on good DSPs.
These DSP errors are not cleared
automatically. If the occurs frequently,
replace the card.
ITG0302 DSP device failure. Operating on
reduced capacity. DSP failed to return
to normal service.
Hardware fault cleared by automatic trap.
ITG0303 DSP subsystem failure. Initiating card
reboot. DSP fatal error detected. Hardware fault cleared by automatic trap.
ITG0304 Cannot write to file. I/O error. Can indicate /C: drive corruption.
ITG0305 Cannot open configuration file. Using
default settings. Can occur after a
reboot.
ITG0306 System messaging error threshold
exceeded. Too many invalid A07 or
X12 messages.
ITG0308 Address translation failure. Call is
released.
ITG0309 Unexpected DSP channel closed.
Channel is unusable.
ITG0310 Cannot open DSP channel.
ITG0311 Unable to get response from
Followercard. Cardcan be unplugged.
ITG0312 Unable to push BOOTP tab file to
Backup Leader.
ITG0350 Gatekeeper RAS reject threshold
exceeded.
ITG0351 Cannot open Gatekeeper
configuration file. Using default
settings.
Major Alarms – Immediate intervention required
These alarms indicate an irrecoverable failure of theIP trunk card. Normal operation can only be
restored through manual intervention.
ITG0400 Fatal self-test failure. Card is out of
service. A fatal self-test diagnostic
error was found.
ITG0401 Reboot threshold exceeded.
Manual intervention required.
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.