200 Install and configure IP Trunk3.01 (and later) node
Tabl e 44
NT6D80 MSDL settings for ITG-Pentium 24-port trunk card DCHIP
Port 0 – SW4 Port 0 – SW8
RS-422-A DTE all off all on
Port 1 – SW3 Port 1 – SW7
RS-422-A DTE all off all on
Port 2 – SW2 Port 2 – SW6
RS-422-A DTE all off all on
Port 3 – SW1 Port 3 – SW5
RS-422-A DTE all off all on
The device number for the MSDL card is configured in LD 17 at the prompt DNUM. Also configure
the device number, using switches S9 and S10, on the MSDL card. S9 designates ones and S10
designates tens. To configure the device number as 14, for example, set S10 to 1 and S9 to 4.
Install filter and NTND26 cable (for MSDL and DCHIP cards in sameLarge System equipment row)
Follow the steps in Procedure 11 "Installing the filter and NTND26 cable for
MSDL and DCHIP cards in the same Large system equipment r" (page
200) to install the filter and NTND26 cable for MSDL and DCHIP cards in
same Large System equipment row.
Procedure 11
Installing the filter and NTND26 cable for MSDLand DCHIP cards in the same
Large system equipment row
Step Action
1Install the bracket forthe 15-pin I/O panel filter connector in one of
the two smaller openings (J2, J3, J4, J5) of the I/O panel of the IPE
Module that contains the DCHIP card.
2Install the 15-pin I/O panel filter connector on the inward side of
the bracket.
3Obtain the correct length of the NTND26 DCHI Interface Cable
Assembly to reach from the D-Channel port connector on the
faceplate of the MSDL card to the outward side of the 15-pin filter
connector installed in the I/O panel of the IPE module that contains
the DCHIP card. See Figure 38 "15-pin filter connector installation"
(page 201).
The NTND26 DCHI Interface Cable Assembly is availablein the
following lengths:
NTND26AA – 6 ft