478 Appendix G Upgrade an ITG Trunk1.0 node to support ISDN signaling trunks
Procedure 81
Installing the DCHIP I/O Panelbreakout cable from the upgrade kit
Step Action
1For the Large System, locate the I/O connector that corresponds to
the leftmost card slot of the ITG 8-port trunk card that is undergoing
the hardware upgrade.
2Disconnect existing ELAN network interface and serial cables.
Remove the existing I/O panel breakout cable.
3Install the new cable (NTCW84LA or NTCW84MA). Be sure to use
the screw provided.
4Reconnect ELAN network interface and serial connectors. For
NTCW80CA cards, install a shielded TLAN cable.
5Tur n to "Install filter and NTND26 cable (forMSDL and DCHIP cards
in same Large System equipment row)" (page 200) to install the
DCHIP connector and MSDL cable.
—End—
Upgrade the ITG 8-port trunk card ITG basic trunk software toITG/ISL trunk software
Use the TM 3.1 ITG Basic Trunkapplication to perform this procedure.
Once TM 3.1 has been upgraded to 6.6 or later,all the configuration data
for the ITG trunk node will havebeen converted.

Step 1 - Remove ITG Trunk 1.0 configuration files

Followthe steps in Procedure 82 "Removingthe ITG Trunk1.0 configuration
files" (page 478) to remove the ITG 1.0 Trunkconfiguration files from the
TABLE,BOOTP and CONFIG directories of every card in the node to be
upgraded.
Procedure 82
Removing the ITG Trunk1.0 configuration files
Step Action
1From the TM 3.1 IP TelephonyGateway - ISDN IP Trunk Main
window, select the card from the lowerhalf of the window and
right-click. A context menu appears. Select Telnet to ITG card.TM
3.1 automatically launches a Telnetsession to the selected card.
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.