206 Install and configure IP Trunk3.01 (and later) node
The ELAN network interface supports 10BaseT operation. The TLAN
network interface supports 10/100BaseT operation. To support the
100BaseT operation on Large Systems, the TLAN network interface
requires specialized I/O panel mounting connectors. These connectors
replace the standard connectors provided on the system.
Cables and connectors for the ELAN and TLAN network interface include
the following:
the NTCW84JA Large System I/O panel filter block
the network interface ITG Card ELAN/TLAN Adapter, foruse with both
D-Chip and non-D-Chip equipped cards. Standard shielded, CAT 5
LAN cables (<100 meters) are recommended to attach the LAN ports
to the local network.
An ITG EMC shielding kit (NTVQ83) must be installedon the ELAN and
TLAN network interface cables to meet regulatory requirements at the
installation site. As shown in Figure 40 "EMC kit deployment" (page 207) on
Figure 40 "EMC kit deployment" (page 207), a ferrite must be placed on
both the ELAN and TLAN network interface cables during installation. Cable
ties are then placed to retain the ferrites in the correct position. This applies
to both Small Systems and Large Systems.
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.