348 TM 3.1 OA and M using TM 3.1 applications
Use the Set Node Time to change the timeand date on the node. The
node time is updated every minutewhile the Card Proper ties is open.
Use the Open log file,Open trace file, and the Open OM file buttons
to view the related files. These files are transferred from the card using
FTP and displayed in Microsoft WordPadon the PC.
The trace file is for expert level debugging(trace must be turned on
through the command line).
The log file contains error messages.
The OM file contains the current Operational Measurements.
Setting the node time is required during initial node installation. TM 3.1
sets the Leader card’s time. The Leader sets the time on all other cards.
Configure date and time for the IP Trunk 3.01 (and later) node
Configure the date and time on the IP Trunk 3.01 (and later) node in order
to have correct time and date stamps in Operational Measurement (OM)
reports, RADIUS Call Accounting reports, error messages and error and
trace logs.
Follow the steps in Procedure 54 "Configure the date and time" (page
348) to configure the date and time.
Procedure 54
Configure the date and time
Step Action
1Select the IP Trunk3.01 (and later) node for which the time and date
is to be configured from the list in the upper part of the window.
2Double-click Leader 0from thelist in the lower part of the window.
The ITG Card Properties Maintenance tab appears.
3Click the Set Node Time button. The Set Node Time dialog box
appears.
4Set the correct date and time.
5Click OK. The clock is updated immediatelyon the Active Leader
card (Leader 0 or Leader 1), which in turn updates the other cards in
the ITG ISL Trunknode.
—End—
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.