ITG-Pentium 24-port trunk card (NT0961AA) 49
During configuration, the error message "F:10" can appear. This error
indicates a missing Security Device. It occurs because Security Devices are
not implemented on ITG Trunk2.0. Ignore this message.
See "ITG-Pentium 24-port trunk card faceplate maintenance display codes"
(page 425) for a complete list of faceplate codes.
Ethernet status LEDs
Ethernet status LEDs for the voice interfaceon the daughterboard display
the Ethernet activity as follows:
Green is always onif the carrier (link pulse) is received from the TLAN
Ethernet hub.
Yellowflashes when there is data activity on the TLAN Ethernet hub.
During heavy traffic, yellow can stay continuouslylit.
There are no Ethernet status LEDs for the ELAN network interface on the
motherboard.
Reset switch
A reset switch on the faceplate allows an operator to manually reset the
card without having to cycle powerto the card. This switchis normally used
following a software upgrade to the card or,alternatively, to clear a fault
condition.
PC Card socket
There are two PC Card sockets. The faceplate socket accepts either a Type
I, a TypeII, or a Type III PC Card and is designated ATAdevice A:. The
internal socket is reserved for the NTWE07AA C7LIU DCH PC Card on
the DCHIP.
Maintenance display
This is a four character, LED-based dot matrix display. It shows the card
boot sequence and is labeled with the card role as follows:
LDR = Active Leader
BLDR = Backup Leader
FLR = Follower
A properly-functioning IP trunk card displays one of the above codes. If an
IP trunk card encounters a problem, a fault code is displayed. For more
information, see "Media Card 32-port trunk card faceplate maintenance
display codes" (page 423) and "ITG-Pentium 24-port trunk card faceplate
maintenance display codes" (page 425).
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.