214 Install and configure IP Trunk3.01 (and later) node
Figure 46
Large System DCHIP cabling setup: intra-column/cube
NTMF04BA MSDL extension cable
The NTMF04BA cable connects the NTND26AA MSDL cable and the
NTMF29BA DCHIP cable, when the Common Equipment shelf and the
IPE shelf are in separate columns and not connected by internal cabling
channels. A 15-way mounting block (A03511331) is shipped with the
NTMF04BA cable. The mounting block, when mounted on the Common
Equipment shelf I/O panel, allows the connection of the NTND26AA and the
NTMF04BA cables. The NTMF04BA cable is then routed externally to the
IPE I/O panel to connect with the NTMF29BA DCHIP.See Figure 47 "Large
system DCHIP cabling setup: inter-column" (page 215).