IP trunk card description 45
Active Leader and Backup Leader interactionWhen a Leader card reboots into service, it sends bootp requests to
check whether an Active Leader card is present. If it receives a bootp
response, this indicates the presence of an Active Leader card and the
rebooting Leader becomes the BackupLeader. If it does not receivea bootp
response, this indicates the absence of an Active Leader andthe rebooting
Leader becomes the Active Leader.
The Backup Leader monitors the heartbeat of the Active Leader by pinging
the Active Leader’s Node IP.In the event of the Active Leader’s failure (that
is, the ActiveLeader is not responding to the pinging of the Node IP address
by the Backup Leader), the Backup Leader takes overthe Active Leader
role, in order to avoid service interruption. The Backup Leader assigns
the Node IP to its voice interfaceand announces its new status to all the
Follower cards. The Followers re-register with the new Active Leader and,
as a result, a new Resource Tableis built immediately.
The Leader 0 and Leader 1 cards keep their node properties synchronized.
The Backup Leader receives a copy of the bootp.1 file,containing the bootp
table, from the Active Leader on bootup and when Node Properties are
downloaded to the Active Leader.
Critical synchronized data includes the following:
•the card index:
— index 1 indicates Leader 0
— index 2 indicates Leader 1
— index 3 or greater indicates Follower
•the Management MAC address (motherboard Ethernet address)
•the Node IP address
•the individual card IP addresses and card TNs for all IP trunk cards in
the IP Trunk3.01 (and later) node
•D-Channel number, card density and First CHID
In the event of a Backup Leader failure,the Leader card generates an
SNMP trap to the TM 3.1 management station, indicating this failure.
If the Active Leader and BackupLeader are reset, removed,or disconnected
from the LAN at the same time, the entire IP Trunk3.01 (and later) node is
put out-of-service. If this situation occurs, manual intervention is required to
recover the system.
Active Leader/Backup Leader and DCHIP card interactionThe Active Leader checks the status of the DCHIP card. The DCHIP card
must constantly inform the Leader of its DCH status and its card status.
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21December 2007
Copyright© 2007, Nor tel Networks
.