222 Install and configure IP Trunk3.01 (and later) node
Prompt Response Description
...
USR ISLD User
IFC SL1 Interface type for D-channel
ISLM 382 Maximum number of Integrated Service Signaling Links
...
SIDE USR Meridian 1/CS 1000M node type
The IFC response entry must have the protocol entered in TM 3.1’s ITG
Node Properties – Card Configuration Protocol pull-down menu.
The MSDL card does not apply to Meridian 1 PBX 11C Cabinet/CS 1000M
Cabinet and Meridian 1 PBX 11C Chassis/CS 1000M Chassis; therefore
the DCGI prompts and responses apply. The feature requires the option
switches on the Cabinet system SDI/DCH card to be set for RS-422 mode
operation.
Configure ISDN feature in Customer Data Block
Use LD 15 to configure the ISDN feature in the CustomerData Block.
LD 15 Configure ISDN feature in Customer Data Block
Prompt Response Description
REQ CHG Change customer data block.
TYPE NET_DATA Gate-opener for networking features
CUST Customer number
0-99 Range for Large System, Call Server 1000E, and
Media Gateway 1000E
0-31 Range for Small System and Media Gateway 1000B.
OPT a....a Options
AC2 aaa bbb ccc ESN call types under AC2 for the INAC feature. For
example, NPA NXX INTL SPN LOC. INAC stands for
automatic insertion of the ESN access code on incoming
calls.
By default, the INAC feature puts all ESN call types except
for CDP under AC1. Enable or disable INAC per trunk
route in LD 16 in the ISDN section of the Route Data Block.
ISDN (NO) YES Enter YES to configure IP Trunk 3.01 (and later) routes.
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.