198 Install and configure IP Trunk3.01 (and later) node
order to tie the shield of the LAN cable to the frame ground forEMC
compliance.
Figure 37
NTMF94EA ELAN, TLAN and serial port cable
—End—
Install shielded TLAN network interface cable
Use Shielded CAT5cable to connect to the ELAN and TLAN network
interfaces on the NTCW84KA cable. To conduct a ground loop test, referto
"Prevent groundloops on connection to external customer LAN equipment"
(page 446) and follow the test procedure.
For DCHIP cards
Connect a shielded CAT5LAN cable from the TLAN subnet hub to the
RJ-45 coupler on the NTCW84KA TLAN network interface.
For non-DCHIP cards
Connect a shielded CAT5LAN cable from the TLAN subnet hub to the
RJ-45 coupler on the NTMF94EA TLAN network interface.
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright© 2007, Nor tel Networks
.