204 Install and configure IP Trunk3.01 (and later) node
Table 4 5
NTAK02SDI/DCH switch settings for IP Trunk 3.01 (and later) DCHIP
Port 1 SW 1-1 SW 1-2
DCH OFF OFF
Port 3 SW 1-3 SW 1-4
DCH OFF OFF
Table 4 6
NTAK02SDI/DCH jumper settings for the IP Trunk3.01 (and later)
DCHIP
Port Jumper
location Strap for
DTE Jumper
location RS422
J7 C – B J9 C – BPort 1
J6 C – B J8 C – B
J4 C – B J2 C – BPort 3
J3 C – B J1 C – B
2Connect the NTAK19FBQuad Serial I/O SDI/DCH Cable (or
equivalent) to the I/O connector for the card slot in which the
SDI/DCH card is installed.
3If the DCHIP card is installed in the main cabinet with the SDI/DCH
card, then use NTWE04AD SDI/DCH Extension Cable (1 ft) from the
NTCW84KA DCH (P5) connector to the NTAK19FBD-Channel port
connector for Port 1 or Port 3.
4If the DCHIP card is installed in the expansion cabinet, then use
NTWE04AC SDI/DCH Extension Cable (10 ft) from the NTCW84KA
DCH (P5) connector to the NTAK19FBD-Channel por t connector
for Port 1 or Port 3.
—End—
Install the serial cable
Follow the steps in Procedure 14 "Installing the serial cable" (page 205) to
install the serial cable.