TransmitIP trunk card configuration data from TM 3.1 to the IP trunk cards 261
NTAG81BAMaintenance Extender cable to provide an extension
between the NTAG81CAPC Maintenance cable and the TM 3.1 PC.
Alternatively,connect the NTAG81BAMaintenance Extender
cable to the female DB-9 connector of the NTCW84KA
Management Port, DCH, and Serial I/O cable for DCHIP
cards, or the NTMF94EA ELAN, TLAN, RS-232-ports cable for
non-DCHIP cards, to create a more permanent connection to the
IP trunk card serial maintenance port.
Neverconnect two ter minals to the faceplate and I/O panel breakout
cable serial maintenance port connectors at the same time.
2Use the following communication parameters forthe TTY ter minal
emulation on the TM 3.1 PC:
9600 baud
8 bits
no parity bit
1 stop bit
When a new IP trunk card starts up and displays "T:20" on the
4-character display,the IP trunk card begins sending BOOTP
requests on the ELAN subnet. A series of dots appears on the TTY.
3Type+++ to bring up the ITG shell CLI prompt:
...+++
When prompted to login, enter the default username and password
as:
VxWorks login: itgadmin
Password: itgadmin
ITG>
4When the ITG shell prompt appears on the TTY,enter the IP address
for the Leader card:
Wait until the display shows "T:21," then enter:
ITG> setLeader "xxx.xxx.xxx.xxx",
"yyy.yyy.yyy.yyy","zzz.zzz.zzz.zzz"
where
"xxx.xxx.xxx.xxx" is the ELAN network interface IP address of
Leader 0 on the ELAN subnet,
Nortel Communication Server 1000
IP TrunkFundamentals
NN43001-563 02.01 Standard
Release 5.5 21December 2007