Chapter 2 Content Switching Module with SSL Commands

ft group

ft group

To enter the fault tolerant submode, and then configure fault tolerance on the CSM, use the ft group command. To remove the fault-tolerant configuration, use the no form of this command.

ft group group-id vlan vlan number

 

 

no ft group

 

 

 

 

 

Syntax Description

 

group-id

ID of the fault-tolerant group. Both CSMs must have the same group

 

 

 

ID. Range is from 1 to 254.

 

 

 

 

 

 

vlan vlan number

Specifies the VLAN over which heartbeat messages are sent by

 

 

 

VLAN number. Both CSMs must have the same VLAN ID. The

 

 

 

range is from 2 to 4095.

 

 

 

 

 

 

 

Defaults

 

This command has no default settings.

 

 

 

Command Modes

 

Module CSM configuration submode

 

 

 

 

Command History

 

Release

Modification

 

 

 

 

 

 

CSM release 1.1(1)

This command was introduced.

 

 

 

 

 

 

CSM-S release 1.1(1)

This command was introduced.

 

 

 

 

Usage Guidelines A fault-tolerant group is comprised of two Catalyst 6500 series switches each containing a CSM configured for fault-tolerant operation. Each fault-tolerant group appears to network devices as a single device. A network may have more than one fault-tolerant group.

When you enter the fault tolerance group submode, the following commands are available:

default—Sets a command to its default.

exit—Saves changes and exits from the subcommand mode; see the “agent (DFP submode)” command section.

failover—Saves changes and exits from the subcommand mode; see the “failover (fault tolerant submode)” command section.

heartbeat-time—Saves changes and exits from the subcommand mode; see the heartbeat-time (fault tolerant submode)” command section.

no—Negates a command or sets the specified command to its defaults.

preempt—Sets optional parameters for a specified IP address. See the “preempt (fault tolerant submode)” command section.

priority—Configures the CAPP port. Range is from 1 to 65535; default is 5002. See the “priority (fault tolerant submode)” command section.