Chapter 2 Content Switching Module with SSL Commands

failed (probe submode)

failed (probe submode)

To set the time to wait before probing a failed server, use the failed command in the SLB probe configuration submode. To reset the time to wait before probing a failed server to default, use the no form of this command.

failed failed-interval no failed

Syntax Description

 

failed-interval

Specifies the interval in seconds before the probe retires a failed

 

 

 

server; the range is from 2 to 65535.

 

 

 

 

 

 

 

Defaults

 

The default value for the failed interval is 300 seconds.

 

 

 

Command Modes

 

SLB probe configuration submode

 

 

 

 

Command History

 

Release

Modification

 

 

 

 

 

 

CSM release 1.1(1)

This command was introduced.

 

 

 

 

 

 

CSM-S release 1.1(1)

This command was introduced.

 

 

 

 

 

 

 

Usage Guidelines

 

This command is used for all probe types.

 

 

 

Examples

 

This example shows how to configure a failed server probe for 200 seconds:

 

 

Cat6k-2(config-slb-probe-http)# failed 200

 

 

probe

 

Related Commands

 

 

 

 

show module csm probe

 