Chapter 2 Content Switching Module with SSL Commands

probe (serverfarm submode)

probe (serverfarm submode)

Syntax Description

Defaults

Command Modes

To associate a probe with a server farm, use the probe command in the SLB serverfarm configuration submode. To disable a specific probe, use the no form of this command.

probe probe-name

no probe probe-name

probe-name

Probe name associated with the server farm.

 

 

This command has no default settings.

SLB serverfarm configuration submode

Command History

 

Release

Modification

 

 

CSM release 1.1(1)

This command was introduced.

 

 

 

 

 

 

CSM-S release 1.1(1)

This command was introduced.

 

 

 

 

 

 

 

Usage Guidelines

 

Each server farm can be associated with multiple probes of the same or different protocols. Protocols

 

 

supported by the CSM include HTTP, ICMP, TCP, FTP, SMTP, Telnet, and DNS.

 

 

 

Examples

 

This example shows how to associate a probe with a server farm:

 

 

Cat6k-2(config-slb-sfarm)# probe general

 

 

probe

 

Related Commands

 

 

 

 

script task

 

 

 

show module csm probe

 

 

 

show module csm serverfarm

 

 

Catalyst 6500 Series Switch Content Switching Module with SSL Command Reference

2-106

OL-7029-01

Page 128
Image 128