device or cable that connects the input signals on one device to the output signals on another device) is often required since both the printer and the print server are usually DTE devices.

The pinouts for the Pony 100, XConnect, and XConnect II Lite RJ45 connector are shown below:

1 2 3 4 5 6 7 8

Print Server (RJ45)

Printer (DB25)

 

 

 

 

 

RJ45

 

 

DTE

DCE

pin

Signal

Signal

pin

pin

1

RTS out*

CTS in

5

4

2

DTR out*

DSR in

6

20

3

Transmit Data

Receive Data

3

2

4

Transmit return

Signal Ground

7

7

5

Receive Return

Signal Ground

7

7

6

Receive Data

Transmit Data

2

3

7

DSR in*

DTR out

20

6

8

CTS in*

RTS out

4

5

*XConnect II models with serial numbers less than 40500 have RTS on pin 8, DTR on pin 7, DSR on pin 2, and CTS on pin 1.

The XConnect 100 serial ports use PC-compatible 9-pin male D-connectors. Note that the standard off-the-shelf 9-pin female to 25-pin male PC cables will require a null modem in order to connect to most printers or terminals. The pinouts are as follows: