OSS (OPERATING SYSTEM SOFTWARE) MESSAGES

OS1296

There is no stockset specified at this time

 

The CLUSTER SET or CLUSTER SET N/R command was entered

 

but the collection of stocks to be used in the print job has not been

 

specified. (Refer to your DocuPrint 96/DocuPrint 96MX LPS PDL

 

Reference.)

Action

Reprogram job to contain a stockset or wait until such a job is running

 

before entering this command.

OS1297

There are no current trays in any cluster

 

The CLUSTER command was entered but no clusters have been

 

defined.

Action

Define the desired cluster. (Refer to your DocuPrint 96/

 

DocuPrint 96MX LPS Operations Reference chapter on setting up

 

print jobs for additional information.)

OS1298

Specified paper tray not present

 

A command was entered that refers to a feeder tray not in the printer

 

configuration.

Action

Reenter the command, using a feeder tray that your system has.

 

(Refer to the chapter on feeder trays in your DocuPrint 96/

 

DocuPrint 96MX LPS Operator Guide.)

OS1300

Number of active forms is nn

 

The maximum number of forms per print job the system will attempt

 

to keep in forms memory is (number 0-64). This message appears at

 

installation when forms memory space is allocated.

Action

None.

 

OS1310 Number of active fonts is nn

 

The maximum number of fonts per print job the system will attempt

 

to keep in memory is (number 0-128). This message appears at

 

installation when font memory space is allocated.

Action

None.

 

 

OS1320

Number of active graphics is nn

 

The maximum number of graphics per print job the system will

 

attempt to keep in GHO memory is (number 16-128). This message

 

appears at installation when graphics memory space is allocated.

Action

None.

 

 

OS1321

Print darkness level is nn.

 

After entering the DARKNESS command with a level parameter, this

message tells you that the value you have entered is accepted. If you enter the DARKNESS command with no parameters, the message tells you the current level setting.

6-24

XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE

Page 102