HIP (HOST INTERFACE PROCESSOR) MESSAGES

HP9420

Host not communicating. See host for reason

 

The HIP DIAGNOSTIC command was entered. The system failed

 

Test 1: (see explanation for message HP9400) or Test 2: system was

 

unable to send a command on OEMI and in turn read the printer

 

status.

Action

1.

If Test 2 failed, diagnostics are terminated.

 

2.

Inspect the 871-CM display (the “host” referred to in the

 

 

message) to learn nature of the failure.

 

3.

Contact Xerox Customer Service and give information

 

 

appearing on the 871-CM display

 

HP9430 Host timed out in test 3. See host for reason

 

HIP diagnostic failed.

Action

1.

Reenter the HIP DIAGNOSTIC command to retry the diagnostic

 

 

test.

2.If the problem recurs, contact your systems specialist or Xerox Customer Service.

HP9431

Line no. n is open

 

The HIP DIAGNOSTIC command was entered. The system failed

 

Test 3 which verifies integrity of 8 parallel data lines. The line number

 

indicated is shorted high.

Action

1.

Inspect the 871-CM display (the “host” referred to in the

 

 

message) to learn the nature of the failure.

 

2.

Contact Xerox Customer Service and give information

 

 

appearing on the 871-CM display and in this message.

HP9432

Line no. n is shorted

 

The HIP DIAGNOSTIC command was entered. The system failed

 

Test 3 which verifies integrity of 8 parallel data lines. The line number

 

indicated is shorted to ground.

Action

1.

Inspect the 871-CM display (the “host” referred to in the

 

 

message) to learn the nature of the failure.

 

2.

Contact Xerox Customer Service and give information

 

 

appearing on the 871-CM display and in this message.

4-16

XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE

Page 38
Image 38