OSS (OPERATING SYSTEM SOFTWARE) MESSAGES

OS1262

Sysgen paper size out of range

 

If a paper size statement is not included in the JDL, the system will

 

use the values specified at SYSGEN. This message indicates that

 

the SYSGEN value is not supported by the IOT.

Action

Perform a MINI SYSGEN and correct the default paper size.

OS1263

Form paper size out of range: xxxxxx.xxx

 

Paper size for form specified in the JSL is not supported by the IOT.

Action

Contact your systems specialist.

 

 

OS1264

Barcode sequence mismatch

 

The IOT detected a sequence number other than the one expected.

Action

Check the job, correct the reason for the mismatch and rerun.

 

 

OS1265

Printer status request already in progress

 

A previous request for printer status is still being processed.

Action

None.

 

 

OS1266

A Barcode was specified, none found

 

The IOT did not detect a barcode where one was expected.

Action

Check Read Head alignment, bar code programming or continue job

 

in BAR OFF mode.

 

 

OS1267

ESS didn’t confirm duplex hint

 

A sheet abort request was sent to the ESS from the IOT because the

 

ESS did not confirm a hint for the second side of a sheet already

 

committed to the paper path.

Action

None.

 

 

OS1268

Bar Align: sheet delivered. Seq1 = nn, Seq2 = nn

 

Sheets with sequence numbers have been read and delivered with

 

the printer operating in the bar align mode. Seq1 - front side, Seq2 -

 

back side.

Action

None.

 

 

OS1269

Bar Align: sheet delivered

 

Sheets were delivered but no sequence numbers were read with the

 

printer operating in the bar align mode.

Action

None.

6-20

XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE

Page 98
Image 98
Xerox DocuPrint 96MX manual OS1262 Sysgen paper size out of range, OS1263 Form paper size out of range