Chapter 2-Additional Conferencing Information

The New Entry Queue dialog box is displayed.

3Define the Entry Queue parameters as for a standard Entry Queue.

For more information about Entry Queue parameters, see the RMX 2000 Administrator’s Guide, Entry Queues on page 4-1.

4In the Cascade field, select Master or Slave depending on the Master/ Slave relationship.

Set this field to Master if:

The Entry Queue is defined on the MCU on level 1 and the dialing is done from level 2 to level 1.

The Entry Queue is defined on the MCU on level 2 and the dialing is done from level 3 to level 2.

Set this field to Slave if the Entry Queue is defined on the MCU on level 2 (Slave) and the dialing is done from MCU level 1 to level 2.

5Click OK.

Cascade-enabled Entry Queues should not be used to connect standard participants to conferences.