Chapter 18-RMX Hardware Monitoring
18-22

Diagnostic Mode

Diagnostic Mode is a debugging tool for performing hardware
diagnostics that detect malfunctions in the hardware component’s
performance. Diagnostics are performed only for the MFA, CPU and
Switch (Cards: MPM, CPU, RTM IP and RTM ISDN). When Diagnostic
Mode is initialized, the MCU is reset and upon restarting, the MCU will
enter Diagnostic Mode. Entering this mode causes the MCU to terminate
all active conferences and prohibits conferences from being established.
Diagnostic Mode is only enabled when connecting directly to the Shelf
Management server. To do so, type in the URL address the Shelf
Management IP address followed by the system flag:
/?DIAG_MODE=true. For example, 172.22.189.51/?DIAG_MODE=true.
You must also be logged in as a SUPPORT user to run diagnostics.
When accessing the Shelf Management server, the content displayed will be
available in English only.