Appendix H-Setting the RMX for Integration Into Microsoft OCS Environment

4Make sure the IP Network Type is set to H.323 & SIP even though SIP will be the only call setup used with Office Communications Server 2007.

5Make sure that the correct parameters are defined for the Signaling Host IP Address, MPM 1 IP Address, MPM 2 IP Address (if necessary), and Subnet Mask.

Make sure that the IP address of the RMX Signaling Host is the same one defined as a trusted host in Office Communications Server 2007.

6Click the SIP Servers tab.

7Make sure that the Registratioin options (Ongoing Conferenferences, Meeting Rooms, Gateway Profiles, Entry Queues and SIP factories) are not selected (check boxes are cleared).

8Make sure that the IP address of the Office Communications Server 2007 is specified and the Server Domain Name is the same as defined in the OCS and in the Management Network for the DNS.

H-22