Appendix H-Setting the RMX for Integration Into Microsoft OCS Environment
H-22
4Make sure the IP Network Type is set to H.323 & SIP even though SIP
will be the only call setup used with Office Communications Server
2007.
5Make sure that the correct parameters are defined for the Signaling
Host IP Address, MPM 1 IP Address, MPM 2 IP Address (if necessary),
and Subnet Mask.
6Click the SIP Servers tab.
7Make sure that the Registratioin options (Ongoing Conferenferences,
Meeting Rooms, Gateway Profiles, Entry Queues and SIP factories) are not
selected (check boxes are cleared).
8Make sure that the IP address of the Office Communications Server
2007 is specified and the Server Domain Name is the same as defined in
the OCS and in the Management Network for the DNS.
Make sure that the IP address of the RMX Signaling Host is the same one
defined as a trusted host in Office Communications Server 2007.