Chapter 17-RMX Administration and Utilities

17-6

2In the MCMS_PARAMETERS tab, the following flags can be modified:
Table 17-2 System Flags – MCMS_PARAMETERS
Flag Description
ALLOW_NON_
ENCRYPT_PARTY_IN_
ENCRYPT_CONF
If YES, allows non-encrypted participants to
connect to encrypted conferences.
Default: No
ALLOW_NON_ENCRYPT
_RECORDING_LINK_IN_
ENCRYPT_CONF
When set to NO (default), the Recording Link
inherits the encryption settings of the
conference. If the conference is encrypted,
the recording link will be encrypted.
When set to YES, it disables the encryption
of the recording link, regardless of the
Encryption settings of the conference and
RSS recorder.
APACHE_KEEP
_ALIVE
_TIMEOUT
If the connection is idle for longer th an the
number of seconds specified by this flag, the
connection to the RMX is terminated.
Value: 1 - 999
Default: 120
Default (JITC_MODE=YES): 15
AUTHENTICATE_USER If the external database application is to be
used to verify that operators are authorized to
log in to the MCU, set the value of this flag to
YES.
If the value of this flag is set to NO, the MCU
database is used to verify that operators are
authorized to log in to the MCU.
Note: If the flag is set to YES, the flow is first
to look in the internal DB and then go out to
the external one.
Flags for SE200 need to be added manually.