Appendix H-Setting the RMX for Integration Into Microsoft OCS Environment

Table H-2New Active Alarms (Continued)

Alarm Code

Alarm Description

 

 

SIP TLS: Registration

This alarm indicates a mismatch between the

handshake failure

security protocols of the OCS and the RMX,

 

preventing the Registration of the RMX to the

 

OCS.

 

 

SIP TLS: Registration server not

This alarm is displayed when the RMX does

responding

not receive a response from the OCS to the

 

registration request in the expected time

 

frame. Possible causes are:

 

The RMX FQDN name is not defined in

 

the OCS pool, or is defined incorrectly.

 

The time frame for the expected

 

response was too short and it will be

 

updated with the next data refresh. The

 

alarm may be cleared automatically the

 

next time the data is refreshed.

 

Alternatively, the OCS Pool Service can

 

be stopped and restarted to refresh the

 

data.

 

The RMX FQDN name is not defined in

 

the DNS server. Ping the DNS using the

 

RMX FQDN name to ensure that the

 

RMX is correctly registered to the DNS.

 

 

SIP TLS: Certificate has expired

The current TLS certificate files have expired

 

and must be replaced with new files.

 

 

SIP TLS: Certificate is about to

The current TLS certificate files will expire

expire

shortly and will have to be replaced to ensure

 

the communication with the OCS.

 

 

SIP TLS: Certificate subject

This alarm is displayed if the name of the

name is not valid or DNS failed

RMX in the certificate file is different from the

to resolve this name

FQDN name defined in the OCS.

 

Note:

 

Occasionally this alarm may be activated

 

without real cause. Resetting the MCU may

 

clear the alarm.

 

 

H-30