Polycom RMX 2000 Administrator’s Guide

17-9

EXTERNAL_DB_
PASSWORD The password associated with the user name
defined for the RMX on the external database
server.
Default: POLYCOM
EXTERNAL_DB_PORT The external database server port used by
the RMX to send and receive XML requests/
responses.
For secure communications set the value to
443.
Default: 5005.
FORCE_STRONG_
PASSWORD_POLICY When set to YES (default when
JITC_MODE=YES), implements the Strong
Password rules. For more details, see
Implementing Strong Passwords” on
page 11-12.
Default: NO
H.263_ANNEX_T Set to NO to send the Content stream without
Annex T and enable Aethra and Tandberg
endpoints, that do not support Annex T, to
process the Content.
Default: YES
HD_THRESHOLD_
BITRATE Sets the minimum bit rate required by
endpoints to connect to an HD Conference.
Endpoints that cannot support this bit rate are
connected as audio only.
Range: 384kbps - 4Mbs (Default: 768)
HIDE
_CONFERENCE
_PASSWORD
If set to YES (default in Enhanced Security
Mode), Conference and Chairperson
Passwords that are displayed in the RMX
Web Client or RMX Manager are hidden
when viewing the properties of the
conference.
default: NO.
Table 17-2 System Flags – MCMS_PARAMETERS (Continued)
Flag Description