enclosure ID values, the drawer ID values, and the

 

slot ID values insqurare brackets ([ ]).

diskGroup

The name of an existing disk group in which you

 

want to create the virtual disk. (To determine the

 

names of the disk groups in your storage array, run

 

the show storageArray profile command.)

newDiskGroup

The name that you want to give a new disk group.

 

Enclose the new disk group name in double

 

quotation marks (" ").

userLabel

The name of the virtual disk that you want to

 

recover. The user label has two parts:

 

• The virtual disk name. Enclose the virtual disk

 

name in double quotation marks (" ").

 

• The world wide name of the virtual disk,

 

virtualDiskWWN, in the form of a 16 byte

 

identifier, for example,

 

60080E500017B4320000000049887D77.

 

Enclose the identifier in double quotation

 

marks (" ").

 

You must enter both the virtual disk name and the

 

world wide name of the virtual disk. You must

 

enter the virtual disk name first.

 

For example: userLabel="engdata"

 

virtualDiskWWN=60080E500017B432000000004

 

9887D77

capacity

The size of the virtual disk that you are adding to

 

the storage array. Size is defined in units of bytes,

 

KB, MB, GB, or TB.

offset

The number of blocks from the start of the disk

 

group to the start of the referenced virtual disk.

raidLevel

The RAID level of the disk group that contains the

 

physical disks. Valid values are 0, 1, 5, or 6.

segmentSize

The amount of data (in KB) that the RAID controller

 

module writes on a single physical disk in a disk

 

group before writing data on the next physical disk.

 

Valid values are 8, 16, 32, 64, 128, 256, or 512.

dssPreallocate

The setting to turn on or turn off allocating virtual

 

disk storage capacity for future segment size

 

changes. To turn on allocation, set this parameter

 

to TRUE. To turn off allocation, set this parameter

 

to FALSE.

SSID

The storage array subsystem identifier of a virtual

 

disk. Use the show virtual disk command to

 

determine the storage array subsystem identifier.

236

Page 236
Image 236
Dell 34XX, 38XX, 32XX, 36XX manual Ssid