Parameter

Description

 

 

 

enclosure. Use the controller parameter only

 

for RAID controller modules with batteries.

NOTE: If you do not specify a RAID controller module, the age is reset for the storage array battery or both RAID controller module batteries. If you specify a RAID controller module, then the age for only that RAID controller module battery is reset.

Reset Storage Array iSCSI Baseline

Description

This command resets the iSCSI baseline for the storage array to 0.

Syntax

reset storageArray iscsiStatsBaseline

Parameters

None.

NOTE: This command resets the baseline to 0 for both RAID controller modules in the storage array. The purpose of resetting both of the RAID controller module baselines is to help ensure that the counts are synchronized between the RAID controller modules. If one RAID controller module resets but the second RAID controller module does not reset, the host is informed that the RAID controller modules are out of synchronization. The host is informed by the time stamps that are reported with the statistics.

Example

-c "reset storageArray iscsiStatsBaseline;"

Reset Storage Array SAS PHY Baseline

Description

This command resets the SAS physical layer (SAS PHY) baseline for all devices except physical disks, and removes the list of errors from the .csv file. The .csv file is generated by running the save storageArray SASPHYCounts command.

NOTE: The reset storageArray SASPHYBaseline command clears error counts for all devices except the physical disks. After running this command, the .csv file continues to list the DrivePHY errors. All other errors are deleted from the .csv file.

Syntax

reset storageArray SASPHYBaseline

260

Page 260
Image 260
Dell 34XX Reset Storage Array iSCSI Baseline, Reset Storage Array SAS PHY Baseline, Reset storageArray iscsiStatsBaseline