Retrieve the performance modeling data using PowerVault MD Storage Manager.

Performance modeling ends, but no data is available when one of the following conditions occurs:

You reboot the RAID controller module.

You make any changes to the SSD cache configuration.

The state of the SSD cache changes.

Start Storage Array Blink

Description

This command identifies a storage array by turning on the indicator LED for the storage array. Use the stop storageArray blink command to turn off the indicator LED for the storage array.

Syntax

start storageArray blink

Parameters

None.

Start Storage Array Configuration Database Diagnostic

Description

This command runs a consistency check against a configuration database.

Syntax

start storageArray configDbDiagnostic [sourceLocation=(disk onboard)]

[diagnosticType = (fileSystem mirror contentCheck)] [controller[(0 1)]]

Parameters

Parameter

Description

 

 

sourceLocation

This parameter specifies the location of the

 

database.

 

disk indicates that data comes directly from

 

the database on the physical disk.

 

onboard indicates that data comes from the

 

RPA memory location

 

The default location is disk.

diagnosticType

The level of diagnostic testing that you want to run

 

on the database. You can run one of these levels of

 

testing:

390

Page 390
Image 390
Dell 32XX, 34XX Start Storage Array Blink, Start Storage Array Configuration Database Diagnostic, Start storageArray blink