Parameters

Parameter

Description

 

 

controller

The identifier letter of the RAID controller module

 

that has the iSCSI host ports. Valid RAID controller

 

module identifier values are 0 or 1, where, 0 is the

 

RAID controller module in slot 0, and 1 is the RAID

 

controller module in slot 1.

iscsi-host-port

The identifier of the port on the storage array on

 

which you want to refresh the DHCP parameters.

 

Enclose the iSCSI host port name in square

 

brackets ([ ]).

NOTE: This operation ends the iSCSI connections for the portal and brings down the portal temporarily.

Start Physical Disk Blink

Description

This command blinks a physical disk by turning on an indicator light on the physical disk. Run the stop physicalDisk blink command to turn off the indicator light on the physical disk.

Syntax

start physicalDisk [enclosureID,slotID] blink

Parameters

Parameter

Description

 

 

physicalDisk

The location of the physical disk that you want to

 

find. For high-capacity expansion enclosures,

 

specify the enclosure ID value and the slot ID value

 

of the physical disk that you want to revive.

 

Enclosure ID values are 0 to 99. Slot ID values are

 

0 to 31. Enclose the enclosure ID value and the slot

 

ID value in square brackets ([ ]).

Start Physical Disk Channel Blink

Description

This command identifies the expansion enclosures that are connected to a specific physical disk port by turning on the indicator lights for the expansion enclosure that is connected to the physical disk port. Use the stop physicalDiskChannel blink command to turn off the indicator lights on the expansion enclosure.

384

Page 384
Image 384
Dell 34XX, 38XX, 32XX, 36XX manual Start Physical Disk Blink, Start Physical Disk Channel Blink, Iscsi-host-port