Parameters

Parameter

Description

 

 

enclosure

Service tag of the RAID enclosure or the expansion

 

enclosure for which you are setting the enclosure

 

ID. You must put quotation marks (" ") around the

 

Service Tag.

id

Specifies the value for the RAID enclosure or

 

expansion enclosure ID. Valid values are 0 through

 

99. You do not need to put parentheses around

 

the enclosure ID value.

Set Event Alert Filtering

Description

The set event alert commands manage alert event notification by either disabling a specific critical event alert from being sent, or by enabling notification about a specific critical event alert to be sent. To prevent notification about a specific critical event alert from being sent, you block it. To enable notification about a specific critical event alert to be sent, you unblock it.

The storage management software supports different priorities of events (such as Informational, Warning, Critical). When you define your storage array, you can configure alerts and define how the event alerts are managed. If you have configured the storage array to send alerts, then a notification is sent to a designated recipient when a Critical event occurs. That notification can be one or all of the following types:

email

syslog

trap notifications

The set event alert CLI commands work on a single storage array. When you run the commands on a storage array, only that storage array is affected by the commands. Other storage arrays that have not had the CLI command run against them have the default behavior.

Blocking an event alert does not prevent the event from being posted to the system event log. All events will continue to be posted to the event log.

Syntax

Syntax to Block an Event Alert

set blockEventAlert eventType

Syntax to Unblock an Event Alert

set unBlockEventAlert eventType

291

Page 291
Image 291
Dell 36XX, 34XX, 38XX, 32XX manual Set Event Alert Filtering, Set blockEventAlert eventType, Set unBlockEventAlert eventType