Dell 38XX, 34XX, 32XX Test Remote Replication Group Connectivity, Suspend ssdCache ssdCacheName

Models: 36XX 32XX 38XX 34XX

1 417
Download 417 pages 18.23 Kb
Page 409
Image 409

Syntax

suspend ssdCache [ssdCacheName]

Parameter

Parameter

Description

 

 

ssdCache

The alphanumeric identifier (including - and _) of

 

the SSD cache that you want to suspend. Enclose

 

the identifier in square brackets ([ ]). If the SSD

 

cache name contains special characters or consists

 

only of numbers, you also must enclose the

 

identifier in double quotation marks (" ") inside

 

square brackets.

Notes

To restart caching, use the resume ssdCache command.

Test Remote Replication Group Connectivity

Description

This command tests possible communication problems between the local storage array and the remote the storage array associated with a remote replication group.

Syntax

diagnose asyncRemoteReplicationGroup ["asyncRemoteReplicationGroupName"] testID=(all connectivity latency bandwidth portConnections)

Parameters

Parameter

Description

 

 

asyncRemoteReplicationGroup

The name of an existing remote replication group

 

that you want to test. Enclose the remote

 

replication group name in square brackets ([ ]). If

 

the remote replication group name has special

 

characters, you also must enclose the remote

 

replication group name in double quotation marks

 

(" ").

testID

The identifier for the diagnostic test you want to

 

run. The identifier and corresponding tests are as

 

follows:

 

All—Performs all the tests associated with this

 

command.

 

Connectivity—Verifies that the two RAID

 

controller modules have a communication

409

Page 409
Image 409
Dell 38XX, 34XX, 32XX, 36XX manual Test Remote Replication Group Connectivity, Suspend ssdCache ssdCacheName