1489

GB

0

%

1675

GB

0

%

1862

GB

0

%

*= Current SSD cache physical capacity.

Stop Storage Array Blink

Description

This command turns off the indicator lights on the storage array that were turned on by the start storageArray blink command.

Syntax

stop storageArray blink

Parameters

None.

Stop Storage Array Configuration Database Diagnostic

Description

This command stops the diagnostic test to validate the configuration database in the RAID controller module firmware that was started by the start storageArray configDbDiagnostic command.

Syntax

stop storageArray configDbDiagnostic

Parameters

None.

Notes

The RAID controller module firmware returns a confirmation that the diagnostic test was cancelled.

In addition, you can start the database configuration diagnostic test through the storage management software GUI; however, you cannot stop the database configuration diagnostic test through the storage management software GUI. If you want to stop a running diagnostic test, you must use the stop storageArray configDbDiagnostic command.

If you try to use the stop storageArray configDbDiagnostic command after validation of the storage array configuration is complete, you do not receive any message that the validation has finished. This behavior is expected.

405

Page 405
Image 405
Dell 38XX, 34XX, 32XX, 36XX Stop Storage Array Blink, Stop Storage Array Configuration Database Diagnostic, 1489 1675 1862