Dell 34XX, 38XX Availability, ServiceMode service, EthernetPort, GlobalNVSRAMByte, HostNVSRAMByte

Models: 36XX 32XX 38XX 34XX

1 417
Download 417 pages 18.23 Kb
Page 300
Image 300

Parameters

Parameter

Description

 

 

controller

The RAID controller module for which you want to

 

define properties. Valid RAID controller module

 

identifiers are 0 or 1, where 0 is the RAID controller

 

module in the top slot, and 1 is the RAID controller

 

module in the bottom slot. Enclose the identifier

 

for the RAID controller module in square brackets

 

([ ]). If you do not specify a RAID controller module,

 

the firmware for the controller returns a syntax

 

error.

availability

The mode for the RAID controller module, which

 

you can set to online, offline, or

 

serviceMode (service).

ethernetPort

The attributes (options) for the management

 

Ethernet ports. The entries to support this

 

parameter are listed in the Syntax Element

 

Statement Data table that follows. Many settings

 

are possible, including setting the IP address, the

 

gateway address, and the subnet mask address.

globalNVSRAMByte

A portion of the RAID controller module NVSRAM.

 

Specify the region to be modified using the starting

 

byte offset within the region and the byte value or

 

bit value of the new data to be stored into the

 

NVSRAM.

hostNVSRAMByte

The NVSRAM for the host-specific region. The

 

setting specifies the host index for the specific

 

host, the starting offset within the region, the

 

number of bytes, and the byte value or bit value of

 

the new data to be stored into the NVSRAM.

IPv4GatewayIP

The IP address of the node that provides the

 

interface to the network. The address format for

 

the IPv4 gateway is (0–255).(0–255).(0–255).

 

(0–255)

IPv6RouterAddress

The IP address of IPv6 router that connects two or

 

more logical subnets. The address format for the

 

IPv6 router is (0–FFFF):(0–FFFF):(0–FFFF):

 

(0–FFFF): (0–FFFF):(0–FFFF):(0–FFFF):

 

(0–FFFF).

iscsiHostPort

This parameter enables you to set options for the

 

iSCSI ports on the RAID controller module. Select

 

the specific iSCSI port and then select the options

 

for that port. The iSCSI port identifier can be 0, 1 or

 

2, 3. Refer to the information about your RAID

 

controller module for the location and identifier of

 

the ports.

300

Page 300
Image 300
Dell 34XX, 38XX, 32XX, 36XX Availability, ServiceMode service, EthernetPort, GlobalNVSRAMByte, HostNVSRAMByte, IPv4GatewayIP