Parameter

Description

 

 

preReadConsistencyCheck

The setting to turn on or turn off preread

 

consistency checking. Turning on preread

 

consistency checking verifies the consistency of

 

RAID redundancy data for the stripes containing

 

the read data. Preread consistency checking is

 

performed on read operations only. To turn on

 

preread consistency checking, set this parameter

 

to TRUE. To turn off preread consistency checking,

 

set this parameter to FALSE.

 

NOTE: Do not use this parameter on non

 

redundant virtual disks, such as RAID 0 virtual

 

disks.

readCacheEnabled

The setting to turn on or turn off the read cache.

 

To turn on the read cache, set this parameter to

 

TRUE. To turn off the read cache, set this

 

parameter to FALSE.

consistencyCheckEnabled

The setting to turn on or turn off the write cache.

 

To turn on the write cache, set this parameter to

 

TRUE. To turn off the write cache, set this

 

parameter to FALSE.

segmentSize

The amount of data (in KB) that the RAID controller

 

module writes on a single physical disk in a virtual

 

disk before writing data on the next physical disk.

 

Valid values are 8, 16, 32, 64, 128, 256, or 512

userLabel

The new name that you want to give an existing

 

virtual disk. Enclose the new virtual disk name in

 

double quotation marks (" ").

writeCacheEnabled

The setting to turn on write cache capability.

Notes

When you use this command, you can specify one or more of the optional parameters.

You can apply these parameters to only one virtual disk at a time:

addCapacity

segmentSize

userLabel

Add Capacity, Add Physical Disks, And Segment Size

Setting the addCapacity parameter, the addPhysicalDisks parameter, or the segmentSize parameter starts a long-running operation that you cannot stop. These long-running operations are performed in the background and do not prevent you from running other commands. To show the progress of long-running operations, use the show virtualDisk actionProgress command.

335

Page 335
Image 335
Dell 36XX Add Capacity, Add Physical Disks, And Segment Size, PreReadConsistencyCheck, AddCapacity SegmentSize UserLabel