snmp-server enable traps linkmode

Mode

Command History

Global Config

Version 2.3

Introduced

Note: The CLI indicates successful execution of this command, and the show trapflags report shows successful execution of the command, but this trap is not currently supported.

Related

 

 

storm-control broadcast

Enable broadcast storm recovery mode.

Commands

 

 

 

show storm-control

Display switch configuration information.

 

 

 

snmp-server enable traps linkmode

This command enables Link Up/Down traps for the entire switch. When enabled, link traps are sent only if the Link Trap flag setting associated with the port is enabled (see ‘snmp trap link-status’ command).

Syntax [no] snmp-server enable traps linkmode

The no version of this command disables Link Up/Down traps for the entire switch.

Default enabled

Mode

Global Config

snmp-server enable traps multiusers

This command enables Multiple User traps. When the traps are enabled, a Multiple User Trap is sent when a user logs in to the terminal interface (EIA 232 or telnet) and there is an existing terminal interface session.

Syntax [no] snmp-server enable traps multiusers

The no version of this command disables Multiple User traps.

Default enabled

Mode

Global Config

100

System Management Commands

Page 100
Image 100
Force10 Networks S2410s manual Snmp-server enable traps linkmode, Snmp-server enable traps multiusers