current unbalance
run state
These LEDs are further explain ed in the Check Starter and T roubleshooting Guide sections.
Unit-Mounted Wye-Delta Starter (Optional)
The 19XL machin e may be equip ped with a wye-d elta starter mount ed on the un it. This
starter is intended for us e wit h low-voltage motors (und er 600 v). It reduces the start ing current
inrush by connecting eac h ph ase of the motor windings int o a wye configuration. T his oc c u rs
during the starting perio d when the motor is acceler at ing up to speed. After a tim e del ay, once
the motor is up to speed, the starter automatically c onn ects the phase winding s int o a delta
configuration.
Click here for Figure 5 — Cu tler-Hammer® Solid-State Starter, Internal Vi ew
Click here for Fig ure 6 — Benshaw, Inc. Soli d-State Starter, Internal View
Click here for Fig ure 7 — Typical Starter F ront View (Solid-State St arter Shown)