CNT RES AUTO MAN

CNTL A 0 1

CNTL I3 0 1

CNTL C 0 1

CNTL D 0 1

Spectrum Analyzer Mode Key Descriptions

Spectrum Analyzer Mode Functions

allows the resolution of the marker counter to be selected manually or auto-coupled. The marker counter has a resolution range of 10 Hz to 100 kHz. The available resolution values are 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, and 100 kHz. The 1 Hz marker counter resolution is not specified. The resolution can be changed by using the step keys or by entering the resolution using the numeric keypad. The marker counter resolution can be auto coupled to the span by pressing CNT NES AUTO MAN so that AUTO

is underlined. The CNT RES AUTO MAN softkey function is

not affected by pressing AUTO ALL .

Front-Panel Key Access [MKRFCTN)

makes the auxiliary-interface control line A output high or low (TTL).

Front-Panel Key Access [AUXCTRL)

makes the auxiliary-interface control line B output high or low (TTL).

Front-Panel Key Access (jj”

makes the auxiliary-interface control line C output high or low (TTL).

Front-Panel Key Access [AUXCTRLI)

makes the auxiliary-interface control line D output high or low (TTL).

Front-Panel Key Access [AUXCTRL)

6-43